Roof systems8 min read

What Do Granules Do on a Spray Foam Roof? Traction, Hail, Fire, and How They Differ From Gravel

Granules can give a coated foam roof traction, some extra protection from hail and, when the tested assembly includes them, part of its fire rating, and they are a different system from the gravel some foam roofs carry. This post covers how they go on, what the hail evidence says, why they can hide damage, and how much weight gravel adds instead.

ByA-1 Roofing

In short

Granules can give a coated foam roof traction, some extra protection from hail and, when the tested assembly includes them, part of its fire rating. Gaco's silicone specification broadcasts them into a final wet coat at 30 pounds per 100 square feet. Gravel aggregate is a separate, much heavier system, and granules can hide hail cracks from an inspector who does not look closely.

What do granules do on a spray foam roof?

IBHS's spray foam roof guide, written with the Spray Polyurethane Foam Alliance (June 2019, a legacy benchmark), names three jobs: granules provide traction, enhance durability and increase fire resistance. It says granules and chips come in a variety of grades and sizes and are typically embedded into wet elastomeric coating, which holds them in place.

On a foam roof the foam is the waterproofing and the coating protects the foam from sunlight. Granules sit on the very top, bedded in the last coat. They are an option added to a coating system, not a replacement for any part of it.

Owners also choose them for looks: granules come in many colors, and A-1 has added them for cosmetic reasons as well as durability.

How are granules put on a foam roof?

They are thrown into wet coating. Gaco's specification for its S20 silicone over spray foam (SPF-S20-38-20, revised June 2021) lists an optional granular coat on top of the full system: one more coat of silicone at no less than 0.5 gallons per 100 square feet, about 8 mils wet, then roofing granules broadcast into it immediately at 30 pounds per 100 square feet.

The word immediately matters. The granules stay because the coat they land in is still wet. A coat that has started to skin over may not hold them.

Gaco's recoat specification (RC-S20-38-20, also revised June 2021) carries the same optional granular coat and calls for white roofing granules at the same 30 pounds per 100 square feet.

These are the two specifications A-1 built to at Woonsocket School District: SPF-S20-38-20 for the 2022 restoration and RC-S20-38-20 for the recoat after hail.

Do granules help a spray foam roof survive hail?

UPC Foam, a spray foam supplier, says they help. Its guide to hail and spray foam roofing draws on two RICOWI hail investigations, one after the 2004 Oklahoma City storm and one after the 2011 Dallas and Fort Worth storm. Its fourth way to raise a foam roof's hail resistance is to top the coating with granules or crushed aggregate; it says field studies show this reduces hail damage more than coating alone, but it does not name the studies.

Granules are one of five items on that list. The same guide recommends foam denser than 3.0 pounds per cubic foot with a compressive strength of 60 psi or more, and a third layer of coating on top of the usual two layers of 10 to 15 mils each, because added thickness raises the coating's tensile strength.

Granules reduce hail damage rather than prevent it. SPF consultant Mason Knowles wrote in 2007 that they "will not prevent impact damage just reduce its effect", and thicker or tougher coatings are the other route.

Hail ratings are a separate question. IBHS's 2019 guide says spray foam roofing assemblies are generally evaluated under FM 4470 and rated for moderate hail (MH) or severe hail (SH), or left unrated. FM has since added a Very Severe Hail (VSH) class tested with 2-inch ice balls, per Carlisle's guide to the rating (updated August 2025). Those ratings belong to the assembly that was tested, so ask whether a bid's hail rating covers the system as quoted, granules included.

A-1's post on what hail does to a spray foam roof covers the hail map and what to do after a storm.

Can granules hide hail damage on a foam roof?

Yes. UPC Foam's guide shows two photos of a granule-surfaced roof after hail with the caption that granules can help reduce hail damage, but can also hide cracks unless investigated more closely.

Hail usually leaves crow's-foot or semicircle cracks in the coating, in UPC's description, and under granules those cracks are easy to miss. A crack left open lets water and sunlight reach the foam.

So a granule roof needs a slower walk after a storm, with the inspector looking at the coating under the granules rather than across the surface. A-1's inspection checklist for spray foam roofs lists what to record.

A-1 has one granule-surfaced job that takes hail in some form every year, sometimes more than once, and it has been recoated twice because of hail. On that roof the hail splits were difficult to find and easily missed. The surface has to be walked very slowly, several times, from different directions.

Each recoat followed the same order: remove the loose granules, repair the punctures, wash the roof, then apply a top coat at 1.5 gallons per 100 square feet.

Where a crack is suspected, a small slit sample cut through the coating shows how deep the damage goes; a 2000 IIBEC paper by Mason Knowles and Don Best calls for at least one slit sample per 2,500 square feet when inspecting after hail.

Do granules make a coated roof safe to walk on?

They help, within limits. Gaco's recoat specification says in capitals that while granules will improve traction, caution should still be exercised when walking on the roof surface, especially in wet conditions. Johns Manville's coatings guide warns that a silicone-coated roof can be very slippery.

For paths that get walked often, Gaco offers a separate optional walkpad: its SF2036 WalkPad coating (or SF4236, which the recoat specification names as the approved walkpad) at 4 gallons per 100 square feet, about 64 mils wet, with safety-yellow granules broadcast into it at 0.5 pounds per 100 square feet. The yellow marks the path as well as gripping it.

Do granules change a foam roof's fire rating?

They are part of it. IBHS's guide says spray foam roofs are generally tested for exterior fire exposure under ASTM E108 and UL 790, and that the results list the material thicknesses that were tested, naming the foam, the coatings and the granules.

So if a rating was earned with granules, the granules are part of what the rating describes. If it was earned without them, adding them is a change to the tested assembly. Either way, the fire rating on a bid should name the same system that goes on the roof.

What is the difference between granules and aggregate on a foam roof?

Weight, mostly, and how they are held. Granules are bedded in a coat of wet coating. Aggregate, gravel or slag, is loose-laid over the foam on flat areas, with sloped and vertical surfaces coated instead. IBHS's guide covers it in a separate section and points to SPFA-110, the Spray Polyurethane Foam Alliance's document on aggregate systems.

IBHS says aggregate can protect foam from sunlight on its own or as a supplement to a coating. The size of the stone matters more than its type: a mix of sizes, with the larger pieces approaching three-quarters of an inch, flat-surfaced rather than round. It should be at least three-quarters of an inch thick overall and kept off slopes greater than half an inch per foot.

Then the load. IBHS puts an aggregate-covered foam roof at about 10 pounds per square foot of added dead load, and says to evaluate the structural loading whenever a roof is reroofed with spray foam. The granules in Gaco's granular coat weigh 30 pounds per 100 square feet, or 0.3 pounds per square foot. That is more than thirty times lighter, but every added load counts on an older deck, so have an engineer confirm the structure before adding any surfacing.

Do granules change how a foam roof is recoated?

Yes. A granule surface takes its own extra coat: Gaco's specifications call for at least 0.5 gallons of silicone per 100 square feet just to hold the granules, and SPF consultant Mason Knowles put the figure at about three-quarters of a gallon per square in a 2007 forum answer. Ask what the next recoat over that surface will involve before you add granules.

Does A-1 put granules on the foam roofs it coats?

Not often. A-1 has installed granules mainly on walk pads, and where a building owner asked for them, and does not usually offer a granule surface unless the owner requests it. When A-1 does use them, it is for durability, and sometimes for looks. A-1 uses light grey granules at about 50 pounds per 100 square feet, which is A-1's practice and heavier than the 30 pounds in Gaco's specification above.

A-1 occasionally sells product to owners who want to patch a small area themselves.

A-1's published spray foam jobs carry two coatings: Gaco S20 silicone at Woonsocket School District, restored again after hail with its 20-year warranty reinstated, and Everest EverCoat HT, a premium acrylic, at Freeman Shopping Center.

On hail-prone foam roofs, A-1's first move is thickness: an extra coat of silicone, with granules on walkways or where the owner wants them. If your foam roof sits in hail country, ask A-1 for a roof assessment and we will walk it and tell you which of those fits your roof and its specification.

What does this post not tell you?

This post summarizes published manufacturer specifications (Gaco's SPF-S20-38-20 and RC-S20-38-20, both revised June 2021), UPC Foam's hail guide, which draws on RICOWI investigations from 2004 and 2011, the IBHS roof guide for spray foam, an IIBEC inspection paper (2000), an industry forum answer (2007) and Carlisle's guide to FM's hail classes. The Gaco specifications (June 2021), the IBHS guide (2019), the Johns Manville guide (2019), the IIBEC paper and forum answer, and the RICOWI investigations behind UPC's guide (2004 and 2011) are all more than 18 months old and are legacy benchmarks. Hail and fire ratings belong to specific tested assemblies, warranties belong to specific manufacturer systems, and neither this post nor A-1 Roofing guarantees how any roof surface will perform in a given storm. It is not structural advice; a building's capacity for added load is for an engineer to confirm.

Questions owners ask next

Can granules be added to an existing coated foam roof?
Yes, as part of a recoat. Gaco's recoat specification includes the optional granular coat, so the granules go into the last wet coat of the new silicone rather than onto the old surface.
How does the building code judge a foam roof's impact resistance?
IBHS's 2019 guide, written against the 2015 International Building Code, says impact resistance of spray foam roof systems is generally determined by the Resistance to Foot Traffic Test in Section 5.5 of FM 4470, a different test from the FM hail ratings.
What color are the granules?
In Gaco's recoat specification, the granular coat uses white roofing granules and the walkpad uses safety-yellow granules. IBHS notes that granules come in a variety of grades and sizes, so the specification on the bid should name the ones being used.
Can I buy granules for a foam roof myself?
A-1 installs granules as part of a roof system. If you are buying granules for your own crew, get the grade and color the coating manufacturer's specification calls for, so the granular coat stays inside its system.

Related on this site

Sources

  1. IBHS — RICOWI roof guide: Spray Polyurethane Foam (Spray Polyurethane Foam Alliance; published June 2019, updated October 2019; legacy benchmark): granules and chips, gravel and slag aggregate, dead load, FM 4470, ASTM E108 and UL 790
  2. Gaco — SPF-S20-38-20, GacoFlex S20 Series over spray polyurethane foam, application specification (revised June 2021, legacy benchmark): optional granular coat at 30 lb per 100 ft², optional walkpad
  3. Gaco — RC-S20-38-20, GacoFlex S20 Series for Re-Coat, application specification (revised June 2021, legacy benchmark): white roofing granules; traction caution
  4. UPC Foam — Hail and SPF Roofing, drawing on RICOWI's 2004 Oklahoma City and 2011 Dallas/Fort Worth hail investigations
  5. Johns Manville — RS-2393 JM Coatings Application Guide (2019, legacy benchmark): silicone surfaces can be very slippery
  6. Carlisle — FM's VSH Testing: Very Severe Hail (February 2020, updated August 2025): 2-inch ice balls, 53–58 ft-lb
  7. IIBEC — Knowles and Best, Inspection, Evaluation and Repair of SPF Roofing Systems after a Windstorm or Hail Event (February 2000, legacy benchmark): slit samples
  8. SprayFoam Magazine forum — Mason Knowles, Foam roof with or without granules (August 2007, legacy benchmark): extra coating, granules reduce hail damage
  9. PM Silicone — SPF roofing: granule colors
  10. A-1 case study — Freeman Shopping Center, Freeman SD
  11. A-1 case study — Woonsocket School District, Woonsocket SD